Violation Detail
Standard Cited: 19180105 B01 Other protective measures.
This violation item has been deleted.
Inspection Nr: 1269900.015
Citation: 01007B
Citation Type: Serious
Abatement Date: 04/13/2018 4
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/27/2018
Nr Instances: 1
Nr Exposed: 8
Related Event Code (REC):
Gravity: 10
Report ID: 0418600
Contest Date: 04/20/2018
Final Order: 07/19/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 07/19/2019 | $0.00 | 04/13/2018 | Serious | |
Penalty | C: Contested | 05/23/2018 | $0.00 | 04/13/2018 | Serious | |
Penalty | Z: Issued | 03/27/2018 | $0.00 | 04/13/2018 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1918.105(b)(1): The employer did not require the wearing of PFDs for each employee engaged in work in which the employee might have fallen into the water: a) Mooring dock located at the Barry Steam Plant's marine terminal: On or about October 7, 2017 and at times prior thereto, the employer did not personal floatation device were used stepping between the dock platform and fleet deck of the Jamie H which exposed an employee to injuries associated with falls up to nine (9) feet and six (6) inches in to the water below.