Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1189275.015
Citation: 01009
Citation Type: Serious
Abatement Date: 05/30/2017 2
Initial Penalty: $6,519.00
Current Penalty: $2,463.00
Issuance Date: 04/10/2017
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC): C
Gravity: 5
Report ID: 0111400
Contest Date: 05/15/2017
Final Order: 10/30/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/30/2017 | $2,463.00 | 05/30/2017 | Serious | |
Penalty | C: Contested | 06/01/2017 | $6,519.00 | 05/30/2017 | Serious | |
Penalty | Z: Issued | 04/10/2017 | $6,519.00 | 05/30/2017 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: Mechanic Shop Area: There were three (3) compressed gas cylinders (oxygen and argon) that were not secured and were subject to being knocked over.