Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1041452.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 10/02/2015 7
Initial Penalty: $2,975.00
Current Penalty: $1,000.00
Issuance Date: 08/17/2015
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 09/04/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/04/2015 | $1,000.00 | 10/02/2015 | Serious | |
Penalty | Z: Issued | 08/17/2015 | $2,975.00 | 10/02/2015 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) An annual/periodic inspection of the energy control procedures has not been conducted for, but not limited to press breaks, ovens, paint booths, paint curing oven process and parts washing conveyor, overhead cranes, and other metal fabricating equipment to ensure that procedures and requirements of the standard are being followed and that employees who implement energy control procedures understand their application.