Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1026286.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 08/30/2015 2
Initial Penalty: $2,380.00
Current Penalty: $1,190.00
Issuance Date: 07/22/2015
Nr Instances: 1
Nr Exposed: 25
Related Event Code (REC):
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 08/03/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/03/2015 | $1,190.00 | 08/30/2015 | Serious | |
Penalty | Z: Issued | 07/22/2015 | $2,380.00 | 08/17/2015 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a)NAMJet LLC, at 4965 Kingston St., Denver, CO 80239: On and before February 3rd, 2015, the employer did not ensure that the pulley associated with the fence motor located at the rear of the Atlantic Shear was guarded, in that, the belt and pulley apparatus guard was missing. This condition exposed employees to in-going nip point hazard.