Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 305336836
Citation: 26026
Citation Type: Serious
Abatement Status: X
Initial Penalty:
Current Penalty:
Issuance Date: 06/10/2002
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 08/12/2002
Gravity:
Report ID: 0253400
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
Text For Citation: 26 Item/Group: 026 Hazard: CRUSHING
N.J.S.A. 34:6A-33(a): The employer did not provide the employees with a place of employment which was free from recognized hazards. LOC: Overhead Garage Doors ! Facility Wide There existed a hazard of crushing injury/death when entering/exiting through any of the overhead garage doors of the Maintenance Facilities. Comment: Some methods of abatement would include (as set forth in ANSI standard A156.8) and the following: 1. A constant pressure actuation switch. This would always be operated in sight of the door so that it could be released and manually reversed if an obstruction was hit. 2. Installation of a reversing edge switch. This would allow an automatic closing control out of sight of the door, but would immediately reverse the direction of the door upon striking an obstruction. A variation to this option would be the use of photoelectric cells that would reverse the door when an obstruction was encountered by the beam. 3. A three-button control switch. If the following conditions are also met: (a) It is provided with a permanent placard adjacent to the switch with the following warning letters at least 1/4" high: WARNING TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR (b) The control station and placard are located within sight of the doorway. (c) Automatic closing controls are not also installed. (d) Operator must remain at the control station and observe the door until the door is fully closed.
Translate