Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1072818.015
Citation: 03003B
Citation Type: Repeat
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/14/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/29/2015
Gravity: 5
Report ID: 0418800
Contest Date: 01/04/2016
Final Order: 08/07/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/07/2017 | $0.00 | 12/29/2015 | Repeat | |
Penalty | C: Contested | 01/25/2016 | $0.00 | 12/29/2015 | Repeat | |
Penalty | Z: Issued | 12/14/2015 | $0.00 | 12/29/2015 | Repeat |
Text For Citation: 03 Item/Group: 003B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): On or about July 21, 2015, at the blending line of the production area, Southern Fiber of Miami LLC, Miami Gardens, FL. An employee was exposed to a caught by hazard while working adjacent to a belt and pulleys which were not guarded. Southern Fiber Inc. (DBA Southern Fiber of Orlando LLC) was previously cited for a violation of this occupational safety and health standard or its equivalent 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 990116, citation number 1, item number 5, and was affirmed as a final order on December 19, 2014, with respect to a workplace located at 230 North Ortman Dr, Orlando, Fl 32805.