Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1077467.015
Citation: 03002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/24/2015
Nr Instances: 3
Nr Exposed: 20
Abatement Date: 06/01/2016
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 01/21/2016
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/21/2016 | $0.00 | 06/01/2016 | Serious | |
| Penalty | Z: Issued | 12/24/2015 | $0.00 | 02/12/2016 | Repeat |
Text For Citation: 03 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: a/ At the Kieserling Line, two inclined belts were unguarded. The maximum height of the pulleys was approximately 62 inches. b/ At the Danieli Line, specifically adjacent to the operator's station, one inclined belt was unguarded. The maximum height of the pulley was approximately 36 inches. St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 908320, citation 1, item 8b, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Translate