Violation Detail
Standard Cited: 19100146 C05 II F Permit-required confined spaces
Inspection Nr: 1771552.015
Citation: 03002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/01/2024
Nr Instances: 1
Nr Exposed: 18
Abatement Date: 11/29/2024
Gravity:
Report ID: 0418400
Contest Date:
Final Order: 12/05/2024
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/01/2024 | $0.00 | 11/29/2024 | Other |
Text For Citation: 03 Item/Group: 002 Hazard:
29 CFR 1910.146(c)(5)(ii)(F): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but the atmosphere within the space was not periodically tested to ensure that the continuous forced air ventilation was preventing the accumulation of a hazardous atmosphere: (a) At the main shop: On or about 8/27/24, and at times prior to, the employer exposed employees to entrapment hazards, in that employees that performed welding operations in mixer truck drums did not have periodic testing of the atmosphere.
Translate