Violation Detail
Standard Cited: 19100146 D05 II Permit-required confined spaces
Inspection Nr: 1280979.015
Citation: 03002
Citation Type: Other
Abatement Date: 06/14/2018 2
Initial Penalty: $726.00
Current Penalty: $700.00
Issuance Date: 05/31/2018
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity:
Report ID: 0625700
Contest Date: 06/20/2018
Final Order: 03/19/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 03/19/2020 | $700.00 | 06/14/2018 | Other | |
Penalty | C: Contested | 06/25/2018 | $726.00 | 06/14/2018 | Other | |
Penalty | Z: Issued | 05/31/2018 | $726.00 | 06/14/2018 | Other |
Text For Citation: 03 Item/Group: 002 Hazard:
29 CFR 1910.146(d)(5)(ii): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not evaluate permit space conditions when entry operations were conducted by testing or monitoring the permit space as necessary to determine if acceptable entry conditions were being maintained during the course of entry operations. On or about 3/8/18, and at times prior thereto, at the Welding Location at 100 Precision Drive, Broussard, LA, the employer did not conduct periodic monitoring of a confined space (IBC) to determine if welding operations created a hazardous atmosphere.