Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1103515.015
Citation: 03002
Citation Type: Repeat
Abatement Date: 05/10/2016 5
Initial Penalty: $15,400.00
Current Penalty: $15,400.00
Issuance Date: 05/02/2016
Nr Instances: 1
Nr Exposed: 9
Related Event Code (REC): C
Gravity: 10
Report ID: 0317000
Contest Date: 05/27/2016
Final Order: 03/01/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | W: Empr Withdrew | 03/01/2017 | $15,400.00 | 05/10/2016 | Repeat | |
Penalty | C: Contested | 08/08/2016 | $15,400.00 | 05/10/2016 | Repeat | |
Penalty | Z: Issued | 05/02/2016 | $15,400.00 | 05/10/2016 | Repeat |
Text For Citation: 03 Item/Group: 002 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) The employer does not provide a means of access from one level of the scaffold to another by use of ladders, stair towers, or other acceptable means. This violation was most recently observed at the property 3018 West Thompson Street, Philadelphia, PA 19121 on November 3, 2015 where employees were performing stucco operations from a fabricated frame scaffold that had no ladders, stair towers, or other safe means of access. The fabricated frame scaffold was approximately thirty-nine (39) feet in height and employees were accessing the fabricated frame scaffold using the integral scaffold frame members and climbing crossbraces. To abate this ongoing violation, the employer must require the use of portable ladders, attachable ladders or equivalent safe means of access. BC STUCCO AND STONE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.451(e)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 978105, CITATION NUMBER 2 ITEM NUMBER 2, ISSUED ON 11/17/14. NOTE: FINAL ORDER DATE - 2/10/15. BC STUCCO AND STONE WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.451(e)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 923007, CITATION NUMBER 1 ITEM NUMBER 2, ISSUED ON 12/20/13. NOTE: FINAL ORDER DATE - 2/13/14.