Violation Detail
Standard Cited: 19100134 M02 I Respiratory Protection.
Inspection Nr: 1584752.015
Citation: 03001B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $1,151.00
Current Penalty: $0.00
Issuance Date: 08/09/2022
Nr Instances: 8
Nr Exposed: 100
Abatement Date: 09/12/2022
Gravity:
Report ID: 0134000
Contest Date:
Final Order: 09/01/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/01/2022 | $0.00 | 09/12/2022 | Other | |
| Penalty | Z: Issued | 08/09/2022 | $1,151.00 | 09/12/2022 | Other |
Text For Citation: 03 Item/Group: 001B Hazard:
29 CFR 1910.134(m)(2)(i): The employer did not establish a record of the qualitative and quantitative fit tests administered to an employee which included the information required by 29 CFR 1910.134(m)(2)(i)(A) through (m)(2)(i)(E): Location - 254 Billerica Road, Chelmsford, MA. On or about 3/21/2022 and ongoing, the employer's fit testing records did not contain the information required by the standard. The records were missing: name and identification of the employee tested, the type of fit test performed, the specific make, model, style and size of respirator tested, and the date of the test.
Translate