Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1540330.015
Citation: 03001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/21/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/02/2022
Gravity:
Report ID: 0418100
Contest Date:
Final Order: 01/21/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/21/2022 | $0.00 | 02/02/2022 | Other | |
Penalty | Z: Issued | 12/21/2021 | $0.00 | 02/02/2022 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii):The employer did not certify that periodic inspections of the energy control procedures had been performed: a) TL6 Foam Machine; on or about June 21, 2021 and at times prior to, the employer did not certify that periodic inspections of the lockout/tagout procedures had been performed, exposing workers to amputation hazards and electrical hazards.