Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1435860.015
Citation: 03001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/06/2020
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 07/21/2020
Gravity:
Report ID: 0111400
Contest Date:
Final Order: 03/31/2020
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/31/2020 | $0.00 | 07/21/2020 | Other | |
Penalty | Z: Issued | 03/06/2020 | $0.00 | 07/21/2020 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: Boxer, Dirt Line: A protruding shaft of the dirt line was not guarded.