Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1435502.015
Citation: 03001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/05/2020
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 04/09/2020
Gravity:
Report ID: 0317700
Contest Date:
Final Order: 04/01/2020
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/01/2020 | $0.00 | 04/09/2020 | Other | |
Penalty | Z: Issued | 03/05/2020 | $0.00 | 04/09/2020 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees: a) Spray Booth: Employees locked-out the power to the spray booth's fans prior to performing work on their blades, and the employer did not provide these employees with lockout/tagout training, as discovered on or about 10/02/2019. ABATEMENT CERTIFICATION REQUIRED