Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1309419.015
Citation: 03001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/26/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/09/2019
Gravity:
Report ID: 0213100
Contest Date: 08/23/2018
Final Order: 01/09/2019
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 01/09/2019 | $0.00 | 01/09/2019 | Other | |
Penalty | C: Contested | 10/25/2018 | $0.00 | 08/30/2018 | Other | |
Penalty | Z: Issued | 07/26/2018 | $0.00 | 08/30/2018 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.134(f)(2): The employer did not ensure that employees using tight fitting face piece respirators pass an appropriate qualitative or quantitative fit test prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. (a) On or about 5/3/2018, in the paint area, for the detailer working with/around flammable hazardous chemicals and wearing 3M half-face respirator with organic vapor cartridges. The employees were not fit tested, either qualitatively or quantitatively, prior to being required to use this respirator by the employer.