Violation Detail
Standard Cited: 19100178 A04 Powered industrial trucks.
Inspection Nr: 1307344.015
Citation: 03001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/30/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/17/2018
Gravity:
Report ID: 0522500
Contest Date: 08/21/2018
Final Order: 03/11/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/11/2020 | $0.00 | 08/17/2018 | Other | |
Penalty | C: Contested | 08/23/2018 | $0.00 | 08/17/2018 | Other | |
Penalty | Z: Issued | 07/30/2018 | $0.00 | 08/17/2018 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. a. On or about March 8, 2018, employees used a Vestil, WP-3737-FD, man basket attachment on the forks of a Yale, Model GLC030VXNURE082, Serial C809V05199H, propane powered forklift to change out light bulbs. The employer did not ensure that the attachment was approved by the forklift's manufacturer prior to use.