Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1227935.015
Citation: 03001
Citation Type: Other
Abatement Date: 07/19/2017
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/23/2017
Nr Instances: 1
Nr Exposed: 20
Related Event Code (REC):
Gravity:
Report ID: 0524700
Contest Date: 07/13/2017
Final Order: 09/05/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/05/2018 | $0.00 | 07/19/2017 | Other | |
Penalty | C: Contested | 07/14/2017 | $0.00 | 07/19/2017 | Other | |
Penalty | Z: Issued | 06/23/2017 | $0.00 | 07/19/2017 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: ALCO Manufacturing Corp., LLC - Elyria, OH: On or about April 19, 2017, the employer certify that inspections of energy control procedures were conducted; the employer did not document the machine or equipment included in inspections of energy control procedures.