Violation Detail
Standard Cited: 19100106 E09 III Flammable liquids.
Inspection Nr: 1119628.015
Citation: 03001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,000.00
Current Penalty: $2,400.00
Issuance Date: 07/13/2016
Nr Instances: 1
Nr Exposed: 8
Abatement Date:
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 08/03/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/03/2016 | $2,400.00 | Serious | ||
Penalty | Z: Issued | 07/13/2016 | $4,000.00 | Serious |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: Maintenance Shop: On, or about, February 3, 2016, rags that had been used with solvents, such as but not limited to, Methyl Ethyl Ketone, a Category 2 flammable liquid with a flashpoint of 25 degrees, F, were disposed of into an open plastic bag instead of a closed metal container.