Violation Detail
Standard Cited: 19100184 E01 Slings.
Inspection Nr: 1101763.015
Citation: 03001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/11/2016
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 04/28/2016
Gravity:
Report ID: 0626600
Contest Date:
Final Order: 05/02/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/02/2016 | $0.00 | 04/28/2016 | Other | |
Penalty | Z: Issued | 04/11/2016 | $0.00 | 04/28/2016 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach. On or about October 27, 2015, and at times prior thereto; a. On the southern part of Building B, employees were using an alloy steel sling on an overhead crane that was without permanently affixed durable identification stating size, grade, rated capacity, and reach. b. On the northern part of Building B, employees were using an alloy steel sling on an overhead crane that was without permanently affixed durable identification stating size, grade, rated capacity, and reach.