Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1156866.015
Citation: 02014B
Citation Type: Willful
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/12/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/22/2016
Gravity: 10
Report ID: 0418600
Contest Date: 01/05/2017
Final Order:
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 01/17/2017 | $0.00 | 12/22/2016 | Willful | |
Penalty | Z: Issued | 12/12/2016 | $0.00 | 12/22/2016 | Willful |
Text For Citation: 02 Item/Group: 014B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) ADA Dash Main Line A900; On or about June 18, 2016 and at times prior thereto, Employee #16 was exposed to caught-in, struck-by, and crush hazards in that the employee was allowed to enter a robotic cell where there were energized robots and other jigs and fixtures to aid in clearing a sensor fault without shutting down the machine in accordance with the established procedure.