Violation Detail
Standard Cited: 19100169 B03 I Air receivers.
Inspection Nr: 1542164.015
Citation: 02014
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,096.00
Current Penalty: $3,000.00
Issuance Date: 01/06/2022
Nr Instances: 5
Nr Exposed: 6
Abatement Date: 06/30/2023
Gravity: 1
Report ID: 0112000
Contest Date:
Final Order: 02/11/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 09/27/2022 | $3,000.00 | 06/30/2023 | Serious | |
Penalty | P: Petition to Mod Abatement | 07/05/2022 | $3,000.00 | 06/30/2023 | Serious | |
Penalty | I: Informal Settlement | 02/11/2022 | $3,000.00 | 02/24/2022 | Serious | |
Penalty | Z: Issued | 01/06/2022 | $4,096.00 | 02/24/2022 | Serious |
Text For Citation: 02 Item/Group: 014 Hazard:
29 CFR 1910.169(b)(3)(i): Compressed air receiver(s) were not equipped with an indicating pressure gauge and one or more spring-loaded safety valves: A. Powder Metal Department: On, or about, September 10, 2021, a gauge and pressure relief valve were not provided on the air receiver tank on Press #87, a Yoshizuka mechanical compacting press. B. Powder Metal Department: On, or about, September 10, 2021, a gauge and pressure relief valve were not provided on the air receiver tank on Press #94, a Yoshizuka mechanical compacting press. C. Powder Metal Department: On, or about, September 10, 2021, a gauge and pressure relief valve were not provided on the air receiver tank on Press #82, a Yoshizuka mechanical compacting press. D. Powder Metal Department: On, or about, September 29, 2021, a gauge and pressure relief valve were not provided on the air receiver tank on Press #80, a Dorst mechanical compacting press. E. Powder Metal Department: On, or about, September 29, 2021, a gauge and a pressure relief valve were not provided on the air receiver tank on Press # 76, a Stokes mechanical compacting press.