Violation Detail
Standard Cited: 19100147 C02 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1542164.015
Citation: 02010
Citation Type: Serious
Abatement Date: 02/24/2022 2
Initial Penalty: $4,096.00
Current Penalty: $3,500.00
Issuance Date: 01/06/2022
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity: 1
Report ID: 0112000
Contest Date:
Final Order: 02/11/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/11/2022 | $3,500.00 | 02/24/2022 | Serious | |
Penalty | Z: Issued | 01/06/2022 | $4,096.00 | 02/24/2022 | Serious |
Text For Citation: 02 Item/Group: 010 Hazard:
29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device which rendered the machine or equipment inoperative: A. Metal Department, Metal Compacting: On, or about, July 15, 2021, Press #47, an Alpha Press hydraulic metal compacting press had been under repair for approximately two weeks. Instead of applying a lockout device, the electrical disconnect was secured in the "off" position using a plastic tie wrap. B. Plastics Department, Pill Room #2: On, or about, August 6, 2021, a B.I.P. Engineering hydraulic pre-former had been under repair since July 22, 2021. Instead of applying a lockout device, a tag was affixed over the circuit breaker with electrical tape.