Violation Detail
Standard Cited: 19101025 E03 I Lead.
Inspection Nr: 1604485.015
Citation: 02009B
Citation Type: Serious
Abatement Date: 01/27/2023 2
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 12/08/2022
Nr Instances: 5
Nr Exposed: 7
Related Event Code (REC): C
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 01/05/2023
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/05/2023 | $0.00 | 01/27/2023 | Serious | |
Penalty | Z: Issued | 12/08/2022 | $14,502.00 | 01/27/2023 | Serious |
Text For Citation: 02 Item/Group: 009B Hazard:
29 CFR 1910.1025(e)(3)(i): The employer did not establish and implement a written compliance program to reduce exposures to or below the permissible exposure limit, solely by means of engineering and work practice controls: On or about August 19, 2022, the bead wire department was not equipped with a change room or showers for use by employees with exposures that exceed the permissible exposure level of 50 micrograms per cubic centimeter. The employer did not have a written lead exposure compliance program for the bead wire production process. Personal air monitoring of the employees cleaning the lead pot on August 19, 2022 revealed the following results: Employee; Time; actual ug/m3 exposure; 8-hr Time-weighted exposure; Comparison to 50 ug/m3 PEL a) Operator; 270 min; 2,817 ug/M3 actual; 1,584.8 ug/M3 8-hr TWA; 31.7 times the PEL b) Bead Wire Lead; 285 min; 1,791 ug/M3 actual; 1,063.6 ug/M3 8-hr TWA; 21.3 times the PEL c) Operator; 420 min; 1,339.7ug/M3 actual; 1,172.2 ug/M3 8-hr TWA; 23.4 times the PEL d) Operator; 397 min; 73.85 ug/M3 actual; 61.1 ug/M3 8-hr TWA; 1.2 times the PEL e) Operator; 255 min; 2,200 ug/M3 actual; 1,168.8 ug/M3 8-hr TWA; 3.4 times the PEL