Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1691931.015
Citation: 02006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $11,292.00
Issuance Date: 01/24/2024
Nr Instances: 3
Nr Exposed: 38
Abatement Date: 02/20/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 02/12/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/12/2024 | $11,292.00 | 02/20/2024 | Serious | |
Penalty | Z: Issued | 01/24/2024 | $11,292.00 | 02/20/2024 | Serious |
Text For Citation: 02 Item/Group: 006A Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: On or about August 16, 2023, employees used "WAYCOOL" fans that did not have a guard installed: a) "WAYCOOL" fan across tensioner machine 11. b) "WAYCOOL" fan by yellow cabinets. c) "WAYCOOL" fan by stack area.