Violation Detail
Standard Cited: 19100134 K Respiratory Protection.
Inspection Nr: 1379391.015
Citation: 02005D
Citation Type: Willful
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/05/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 09/17/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/05/2019 | $0.00 | Willful |
Text For Citation: 02 Item/Group: 005D Hazard:
29 CFR 1910.134(k): The employer did not provide effective training to employees who are required to use respirators (Construction Reference 1926.103) a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut and remove a boiler pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work requiring the use of a respirator. The employer did not provide effective training to the employee when respirator use was required. NO ABATEMENT CERTIFICATION REQUIRED