Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1158672.015
Citation: 02004B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/29/2016
Nr Instances: 2
Nr Exposed: 30
Abatement Date: 07/15/2017
Gravity:
Report ID: 0522300
Contest Date: 08/26/2016
Final Order: 08/07/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/07/2017 | $0.00 | 07/15/2017 | Other | |
Penalty | C: Contested | 08/29/2016 | $0.00 | 08/18/2016 | Repeat | |
Penalty | Z: Issued | 07/29/2016 | $0.00 | 08/18/2016 | Repeat |
Text For Citation: 02 Item/Group: 004B Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) on a annual basis: a. On or about June 29, 2016, employees required to use half-face tight-fitting respirators while spray finishing had not received a fit test. b. On or about June 29, 2016, employees voluntarily using full-face tight-fitting respirators in the CNC department had not received a fit test. Norton Industries, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(f)(1), which was contained in OSHA inspection number 1062769, citation number 2, item number 3(c) and was affirmed as a final order on September 23, 2015, with respect to a workplace located at 1366 West 117th Street Lakewood, OH 44107.