Violation Detail
Standard Cited: 19101025 I03 I Lead.
Inspection Nr: 1377734.015
Citation: 02004
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $20,420.00
Current Penalty: $14,282.00
Issuance Date: 07/09/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 11/06/2019
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 08/06/2019
Related Event Code (REC):
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/06/2019 | $14,282.00 | 11/06/2019 | Repeat | |
Penalty | Z: Issued | 07/09/2019 | $20,420.00 | 08/23/2019 | Repeat |
Text For Citation: 02 Item/Group: 004 Hazard:
29 CFR 1910.1025(i)(3)(i): Employee(s) exposed to lead in excess of the permissible exposure limit (PEL), without regard to the use of respirators, were not required to shower at the end of the work shift: In the firing range, where the employer did not require employees who worked in the firing range and who were exposed to lead in excess of the permissible exposure limit (PEL) to shower at the end of the work shift. (a) Personal air monitoring conducted on April 2, 2019, during an 8-hour work shift indicated that an employee was exposed to airborne lead concentrations of 67 micrograms per cubic meter which exceeded the Permissible Exposure Limit (PEL) of 50 micrograms per cubic meter by approximately 1.3 times. (b) Personal air monitoring conducted on April 2, 2019, during an 8-hour work shift indicated that an employee was exposed to airborne lead concentrations of 180 micrograms per cubic meter which exceeded the Permissible Exposure Limit (PEL) of 50 micrograms per cubic meter by approximately 3.7. Frisco Gun Club was previously cited for violation of this occupational safety and health standard 1910.1025(i)(3)(i), which was contained in OSHA Inspection 1070947, Citation 1 Item 8b and was affirmed as a final order on March 15, 2016.