Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1255862.015
Citation: 02004
Citation Type: Other
Abatement Date: 02/16/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/29/2018
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity:
Report ID: 0522500
Contest Date:
Final Order: 02/21/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/21/2018 | $0.00 | 02/16/2018 | Other | |
Penalty | Z: Issued | 01/29/2018 | $0.00 | 02/16/2018 | Other |
Text For Citation: 02 Item/Group: 004 Hazard:
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards. a. On or about August 17, 2017, located in the coil and plate storage building, the employer did not ensure that an oxygen cylinder was secured to prevent it from being knocked over.