Violation Detail
Standard Cited: 19100134 E01 Respiratory Protection.
Inspection Nr: 1418007.015
Citation: 02003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,639.00
Current Penalty: $9,639.00
Issuance Date: 01/24/2020
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 5
Report ID: 0316700
Contest Date: 02/18/2020
Final Order: 08/28/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/28/2020 | $9,639.00 | Serious | ||
Penalty | C: Contested | 02/21/2020 | $9,639.00 | Serious | ||
Penalty | Z: Issued | 01/24/2020 | $9,639.00 | Serious |
Text For Citation: 02 Item/Group: 003A Hazard:
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Cleveland Brothers Welding Area - The employer did not provide medical evaluations for employees who are required to wear Miller PAPRs for overexposures to hexavalent chromium on or about July 25, 2019. No abatement certification or documentation required.