Violation Detail
Standard Cited: 19100213 B03 Woodworking machinery requirements.
Inspection Nr: 960969.015
Citation: 02003
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/14/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/08/2014
Gravity:
Report ID: 0936100
Contest Date:
Final Order: 04/18/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/18/2014 | $0.00 | 05/08/2014 | Other | |
| Penalty | Z: Issued | 04/14/2014 | $0.00 | 05/08/2014 | Other |
Text For Citation: 02 Item/Group: 003 Hazard:
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: Maintenance Shop: On March 4, 2014, and at times prior thereto, the JET Gold Series table saw, model JTAS10-1, was not provided with anti-restart control thus exposing employees to lacerations and amputations.
Translate