Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1686481.015
Citation: 02003
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 01/26/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 02/22/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 02/21/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/21/2024 | $16,131.00 | 02/22/2024 | Other | |
Penalty | Z: Issued | 01/26/2024 | $16,131.00 | 02/22/2024 | Serious |
Text For Citation: 02 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about July 27, 2023, throughout the facility, the employees performed servicing and maintenance on various machinery and equipment such as, but not limited to the DRB #8201 tire machine. Lockout procedures had not been inspected annually.