Violation Detail
Standard Cited: 19100146 E01 Permit-required confined spaces
Inspection Nr: 1206035.015
Citation: 02003
Citation Type: Willful
Abatement Date: 08/11/2017 4
Initial Penalty: $119,503.00
Current Penalty: $0.00
Issuance Date: 07/20/2017
Nr Instances: 1
Nr Exposed: 44
Related Event Code (REC): R
Gravity: 5
Report ID: 0213900
Contest Date: 08/04/2017
Final Order: 12/29/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 12/29/2021 | $0.00 | 08/11/2017 | Willful | |
Penalty | C: Contested | 08/07/2017 | $119,503.00 | 08/11/2017 | Willful | |
Penalty | Z: Issued | 07/20/2017 | $119,503.00 | 08/11/2017 | Willful |
Text For Citation: 02 Item/Group: 003 Hazard:
29 CFR 1910.146(e)(1): Before entry is authorized, the employer does not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit: A recent example of the employer's violative conduct occurred on this occasion: a) 9000 River Rd, Delair, NJ, 08110- Anodizing: The employer did not prepare an entry permit when employees entered anodizing tanks for cleaning, on or about 2/3/2017. To abate this violation, the employer must develop and implement a procedure to ensure that an entry permit is prepared prior to entering any permit required confined spaces including, but not limited to, the anodizing tanks. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, AND PURSUANT TO 29 CFR 1903.19, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, INCLUDING THE STEPS IT IS TAKING TO ENSURE THAT A PROCEDURE IS DEVELOPED AND IMPLEMENTED TO PREPARE AN ENTRY PERMIT PRIOR TO EMPLOYEE ENTRY INTO THE ANODIZING TANK. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19. ALUMINUM SHAPES LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD 29 CFR 1910.146(e)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1059368, CITATION NUMBER 1, ITEM NUMBER 7 AND WAS AFFIRMED AS A FINAL ORDER ON 7/5/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 9000 RIVER ROAD, DELAIR, NEW JERSEY, 08110.