Violation Detail
Standard Cited: 19100219 M01 I Mechanical power-transmission apparatus.
Inspection Nr: 1228330.015
Citation: 02002F
Citation Type: Willful
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/24/2017
Nr Instances: 10
Nr Exposed: 4
Abatement Date: 11/16/2017
Gravity: 10
Report ID: 0419400
Contest Date: 11/16/2017
Final Order: 08/15/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/15/2018 | $0.00 | 11/16/2017 | Willful | |
Penalty | C: Contested | 01/18/2018 | $0.00 | 11/16/2017 | Willful | |
Penalty | Z: Issued | 10/24/2017 | $0.00 | 11/16/2017 | Willful |
Text For Citation: 02 Item/Group: 002F Hazard:
29 CFR 1910.219(m)(1)(i): Standard conditions shall be secured by the use of the following materials. Expanded metal, perforated or solid sheet metal, wire mesh on a frame of angle iron, or iron pipe securely fastened to floor or to frame of machine. (a) Facility - On or about April 26, 2017 machine guarding was mounted to rollers which allowed exposure to pinch points and caught-in hazards. At the following locations: -Line A, Balebreakers, Pickers 1, 2, 3, 4, 5; -Line B, Balebreakers, Pickers 1, 2, 3, 4, 5.