Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1697020.015
Citation: 02002C
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $85,938.00
Current Penalty: $0.00
Issuance Date: 01/12/2024
Nr Instances: 10
Nr Exposed: 10
Abatement Date: 02/15/2024
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/01/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/01/2024 | $0.00 | 02/15/2024 | Repeat | |
Penalty | Z: Issued | 01/12/2024 | $85,938.00 | 02/15/2024 | Repeat |
Text For Citation: 02 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: (A):Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a) On or before 9/1/2023, the employer did not provide each Team Leaders of the Fabric Injection lines with adequate authorized employee training, in that employees were not trained to understand how to control energy sources prior to the start of cleaning operations. Employees did not receive the training necessary to recognize each hazardous energy source including natural gas, and electric, and how and when to secure each energy source for machinery such as but not limited to the Margasa Fiber Injection Line (model #IFPR-3/2100) cells #5, #6, #30, #31. #32, #33, and #34. The UGN Automotive Inc. DBA UGN Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(7)(i)(A), which was contained in OSHA inspection number 1437513, citation number 1, item number 1b and was affirmed as a final order on 2/5/2020, with respect to a workplace located at 201 Exploration Dr. Monroe, OH. 45050