Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1638713.015
Citation: 02002C
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/16/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/11/2023
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 04/07/2023
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/07/2023 | $0.00 | 04/11/2023 | Repeat | |
Penalty | Z: Issued | 03/16/2023 | $0.00 | 04/11/2023 | Repeat |
Text For Citation: 02 Item/Group: 002C Hazard:
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). (a) On December 13, 2022; the employer did not ensure that employees working in a 6.4 foot deep trench with 72 degree walls and type B soil were protected from cave-in hazards. NOTE - Abatement certification AND documentation are required for this item. HMH Construction LLC was previously cited for a violation of this occupational safety and health standard 1926.21(b), which was contained in OSHA inspection number 1455786, Citation 1, Item 4 and was affirmed as a final order on March 23rd, 2020, with respect to a workplace located at 3500 West Franklin Road, Meridian, ID 83642.