Violation Detail
Standard Cited: 19100334 A01 Use of equipment.
Inspection Nr: 1669173.015
Citation: 02002B
Citation Type: Other
Abatement Status: Quick Fix
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/29/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity:
Report ID: 0627500
Contest Date:
Final Order: 09/21/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/21/2023 | $0.00 | Other | ||
Penalty | Z: Issued | 08/29/2023 | $0.00 | Other |
Text For Citation: 02 Item/Group: 002B Hazard:
29 CFR 1910.334(a)(1):Portable electric equipment was not handled in a manner which would not cause damage: On the Production Floor: On or about May 10, 2023, employees were exposed to electrical shock hazards due to a flexible electrical cord being hung with metal wiring in the rear of Makino CNC Vertical Machine (Serial #V130537 / Model #PS95) that could damage the outer jacket or insulation.