Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1304388.015
Citation: 02002B
Citation Type: Serious
Abatement Date: 09/28/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/20/2018
Nr Instances: 1
Nr Exposed: 16
Related Event Code (REC): A
Gravity: 10
Report ID: 0830600
Contest Date: 10/11/2018
Final Order: 10/15/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/15/2019 | $0.00 | 09/28/2018 | Serious | |
Penalty | C: Contested | 10/11/2018 | $0.00 | 09/28/2018 | Willful | |
Penalty | Z: Issued | 09/20/2018 | $0.00 | 09/28/2018 | Willful |
Text For Citation: 02 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources: a) SSM presses: On or about March 23, 2018, and at times prior, press operators and trimmers were exposed to severe crushing injuries while performing die changes on IDRA and IDRA Prince presses, including Model OL/320 I PRP; Serial No. 7110, when the air supply line providing more than 100 p.s.i. air pressure to enclosure door pneumatic actuators was not locked in the closed position and residual pressure bled off. Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).