Violation Detail
Standard Cited: 19100107 D09 Spray finishing using flammable and combustible materials.
Inspection Nr: 1127410.015
Citation: 02002B
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/22/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/26/2016
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 09/13/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/13/2016 | $0.00 | 09/26/2016 | Repeat | |
Penalty | Z: Issued | 08/22/2016 | $0.00 | 09/26/2016 | Repeat |
Text For Citation: 02 Item/Group: 002B Hazard:
29 CFR 1910.107(d)(9): Air exhaust from spray operations was directed so that it could contaminate makeup air being introduced into the spraying area or other ventilating intakes, or directed so as to create a nuisance. Air exhausted from spray operations was recirculated: a) In the Batch Building, where the big batch spray booth exhaust system discharged into the interior of the building. Outdoor Furniture Refinishing, Inc. doing business as Allied Powder Coating was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.107(d)(9), which was contained in OSHA inspection number 950210, citation number 1, item number 9b, and was affirmed as a final order on June 24, 2014, with respect to a workplace located at 6011 St. Augustine, Houston, TX 77021.