Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1475467.015
Citation: 02002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $9,639.00
Issuance Date: 11/10/2020
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 11/20/2020
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 11/25/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/25/2020 | $9,639.00 | 11/20/2020 | Serious | |
Penalty | Z: Issued | 11/10/2020 | $9,639.00 | 11/20/2020 | Serious |
Text For Citation: 02 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: A) Centrex Plastics, LLC, doing business as American Plastics, located at 814 W Lima St, Findlay, OH 45840: On or about May 16, 2020, the employer did not adequately train employees to lockout/tagout equipment such as, but not limited to, the Toshiba Plastic Injection Molding Press # 51 (Model: ISF720SI-59A; Serial # 415705). Employees did not control all hazardous energy sources such as, but not limited to, electrical before conducting activities such as, but not limited to, cleaning "blow backs" (cleaning plastic from the material well on the press) in a close proximity to the energized electrical heater wires. Employees were exposed to 240 volts electrical hazards.