Violation Detail
Standard Cited: 19100146 K03 II Permit-required confined spaces
Inspection Nr: 415682.015
Citation: 02002
Citation Type: Willful
Abatement Date: 11/02/2012 2
Initial Penalty: $49,000.00
Current Penalty: $24,500.00
Issuance Date: 11/01/2012
Nr Instances: 4
Nr Exposed: 30
Related Event Code (REC): C
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 11/20/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/20/2012 | $24,500.00 | 11/02/2012 | Willful | |
Penalty | Z: Issued | 11/01/2012 | $49,000.00 | 11/02/2012 | Willful |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.146(k)(3)(ii): To facilitate non entry rescue, retrieval systems attached to a mechanical device or fixed point outside the permit space in such a manner that rescue can begin as soon as the rescuer becomes aware that rescue is necessary. A mechanical device shall be available to retrieve personnel from vertical type permit spaces more than 5 feet (1.52 m) deep: a. On or about May 1, 2012, employees were required to enter permit required confined spaces. The entrant employees were not provided with a mechanical lifting device for use in the assistance of a non entry rescue, thereby exposing employees to the hazards associated with permit required confined spaces. 1. Main wash building - Bay 1 and 4 were missing a mechanical lifting device. 2. North building - Bay 2 was missing amechanical lifting device. 3. Steam rack bay - East Bay was missing a mechanical lifting device.