Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1827637.015
Citation: 02002
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/30/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity:
Report ID: 0317500
Contest Date:
Final Order: 07/25/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 05/30/2025 | $0.00 | Other |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension was not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder: a) Job site, near 46 South Street, Sewickley, PA: On or about May 29, 2025 during roofing work, the employer did not ensure the ladder used to get up to/down from the roof was properly set up in that it was determined that it only extended approximately 30 inches above the roofline.