Violation Detail
Standard Cited: 19100147 C07 III B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1588430.015
Citation: 02002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $10,000.00
Issuance Date: 09/09/2022
Nr Instances: 2
Nr Exposed: 40
Abatement Date: 10/02/2023
Gravity: 10
Report ID: 0524200
Contest Date: 10/03/2022
Final Order: 08/16/2023
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/16/2023 | $10,000.00 | 10/02/2023 | Other | |
Penalty | C: Contested | 10/05/2022 | $14,502.00 | 09/28/2022 | Serious | |
Penalty | Z: Issued | 09/09/2022 | $14,502.00 | 09/28/2022 | Serious |
Text For Citation: 02 Item/Group: 002 Hazard:
1910.147(c)(7)(iii)(B) Additional retraining shall also be conducted whenever a periodic inspection under paragraph (c)(6) of this section reveals, or whenever the employer has reason to believe that there are deviations from or inadequacies in the employee's knowledge or use of the energy control procedures. Mogul 5 ? On or about March 15, 2022, the employer did not provide sufficient retraining after a periodic inspection revealed a potential discrepancy in the M5 Stacker procedure.