Violation Detail
Standard Cited: 19101027 K01 Cadmium
Inspection Nr: 1460679.015
Citation: 02002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/30/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/13/2020
Gravity:
Report ID: 0524700
Contest Date:
Final Order: 05/27/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/27/2020 | $0.00 | 05/13/2020 | Other | |
| Penalty | Z: Issued | 04/30/2020 | $0.00 | 05/13/2020 | Other |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.1027(k)(1): Surfaces were not maintained as free as practicable of accumulations of cadmium: a) Ball, Bounce, and Sport, Inc. (d.b.a. Hedstrom Plastics.) located at 211 West Geneva Street in Dunkirk, Ohio. On or about February 4, 2020 the employer did not ensure surfaces were maintained as free as practicable of accumulations of cadmium. Employees working in the mixing area were exposed hazards associated with cadmium in that the work table in the mixing area had accumulations of cadmium, 16.8 micrograms per 100 square centimeters, on its surface.