Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1456731.015
Citation: 02002
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $134,937.00
Current Penalty: $94,597.58
Issuance Date: 07/06/2020
Nr Instances: 2
Nr Exposed: 25
Abatement Date: 07/30/2020
Gravity: 10
Report ID: 0524200
Contest Date: 07/29/2020
Final Order: 04/12/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/12/2021 | $94,597.58 | 07/30/2020 | Repeat | |
Penalty | C: Contested | 09/14/2020 | $134,937.00 | 07/30/2020 | Repeat | |
Penalty | Z: Issued | 07/06/2020 | $134,937.00 | 07/30/2020 | Repeat |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer does not conduct periodic inspections of energy control procedures at least annually to ensure that the procedures and requirements of 29 CFR 1910.147 are being followed. This violation was most recently documented at the address located above, as follows: a) Production Area - On or about January 22, 2020, and subsequent dates the employer failed to conduct periodic inspections of each energy control procedure at least annually to verify that the specific procedures for equipment, such as the Mogul 5 Feeder, were adequate and were being applied correctly. b) Production Area - On or about January 23, 2020, and subsequent dates the employer failed to conduct periodic inspections of each energy control procedure at least annually to verify that the specific procedures for equipment, such as the Mogul 5 Stacker, were adequate and were being applied correctly. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. Ferrara Candy Company was previously cited for a violation of this Occupational Safety and Health Standard, 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 1318823, citation number 1, item number 1, and was affirmed as a final order on December 14, 2018, with respect to a workplace located at 7301 Harrison St., in Forest Park, Illinois.