Violation Detail
Standard Cited: 19100265 C18 I Sawmills.
Inspection Nr: 1374648.015
Citation: 02002
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $116,686.00
Current Penalty: $11,500.00
Issuance Date: 07/17/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 08/14/2019
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 08/08/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/08/2019 | $11,500.00 | 08/14/2019 | Repeat | |
Penalty | Z: Issued | 07/17/2019 | $116,686.00 | 08/14/2019 | Willful |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.265(c)(18)(i): Standards. Construction, operation, and maintenance of conveyors shall be in accordance with American National Standard B20.1-1957, which is incorporated by reference as specified in Sec. 1910.6. Section 602 Pulleys, Sprockets, Sheaves, Drums, Blocks: Employees working around the Outside Small Bark Conveyor located in the boiler area were exposed to ingoing nip points and caught in hazards from the unguarded tail pulley when the employer would remove the tail pulley guard in the winter months.