Violation Detail
Standard Cited: 19100029 B02 I Fall protection systems and falling object protection-criteria and practices.
This violation item has been deleted.
Inspection Nr: 1242908.015
Citation: 02002
Citation Type: Other
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/22/2017
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC): C
Gravity:
Report ID: 0112000
Contest Date: 09/15/2017
Final Order: 06/22/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/22/2018 | $0.00 | Other | ||
Penalty | C: Contested | 09/18/2017 | $0.00 | Other | ||
Penalty | Z: Issued | 08/22/2017 | $0.00 | Other |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.29(b)(2)(i): Midrails were not installed at a height midway between the top edge of the guiderail system and the walking-working surface: Mezzanine, Floor Hatch Area: On, or about, June 23, 2017, three sides of the railing system provided around the floor opening had the midrail installed 18 inches above the floor instead of approximately 21 inches, which would have been midway between the floor and top rail.