Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100272 G01 II Grain handling facilities.

Inspection Nr: 1133334.015

Citation: 02002

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $124,709.00

Current Penalty: $12,471.00

Issuance Date: 09/09/2016

Nr Instances: 1

Nr Exposed: 3

Abatement Date: 12/28/2018

Gravity: 10

Report ID: 0728900

Contest Date: 09/29/2016

Final Order: 12/28/2018

Related Event Code (REC): A

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 12/28/2018 $0.00 09/19/2016 Willful  
Penalty F: Formal Settlement 12/28/2018 $12,471.00 12/28/2018 Serious  
Penalty C: Contested 11/08/2016 $124,709.00 09/19/2016 Willful  
Penalty C: Contested 11/08/2016 $124,709.00 09/19/2016 Willful  
Penalty Z: Issued 09/09/2016 $124,709.00 09/19/2016 Willful  
Penalty Z: Issued 09/09/2016 $124,709.00 09/19/2016 Willful  

Text For Citation: 02 Item/Group: 002 Hazard:

29 CFR 1910.272(g)(1)(ii): Prior to bin entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods: The employer is failing to protect each employee entering a grain storage bin from hazards including, but not limited to amputation, entanglement, crushing injuries, and engulfment by not de-energizing, locking out, and tagging out the electrical sub-floor auger. This was most recently documented at a worksite located at 7940 Hayland Avenue, Prosser, Nebraska on March 16, 2016, Employee #3 entered West McPherson/Bin 31 to use a conduit pole to help clear soybean debris that was clogging unguarded sump/floor openings during the operation of the sub-floor auger. At the time of entry, Bin 31 contained approximately 50,000 to 60,000 bushels of soybeans. On March 16, 2016, employee #3 was fatally injured by asphyxiation when his rope lifeline became entangled with the running sub-floor auger in Bin 31. To abate this violation, the employer must assure that each time an employee enters a grain storage structure at the facility, all mechanical, electrical, hydraulic, and pneumatic equipment is de-energized, disconnected, locked out, tagged out, blocked-off, or otherwise effectively prevented from operating. 29 CFR 1910.272(g)(1)(ii): Prior to bin entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods: The employer is failing to protect each employee entering a grain storage bin from hazards including, but not limited to amputation, entanglement, crushing injuries, and engulfment by not de-energizing, locking out, and tagging out the electrical sub-floor auger. This was most recently documented at a worksite located at 7940 Hayland Avenue, Prosser, Nebraska on March 15, 2016, when employees #2 and #3 entered West McPherson/Bin 31 to use a rod or pole to help clear soybean debris that was clogging unguarded sump/floor openings during the operation of the sub-floor auger. At the time of entry, Bin 31 contained approximately 50,000 to 60,000 bushels of soybeans. To abate this violation, the employer must assure that each time an employee enters a grain storage structure at the facility, all mechanical, electrical, hydraulic, and pneumatic equipment is de-energized, disconnected, locked out, tagged out, blocked-off, or otherwise effectively prevented from operating.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.