Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1125762.015
Citation: 02002
Citation Type: Willful
Abatement Status: Abatement Completed
Initial Penalty: $60,500.00
Current Penalty: $48,000.00
Issuance Date: 08/01/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/08/2016
Gravity: 5
Report ID: 0418600
Contest Date:
Final Order: 08/24/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/24/2016 | $48,000.00 | 08/08/2016 | Willful | |
Penalty | Z: Issued | 08/01/2016 | $60,500.00 | 08/08/2016 | Willful |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Rolling Mill Line #1; On or about March 9, 2016 and at times prior thereto, the employer exposed employees to potential hazardous electrical, mechanical, hydraulic and pneumatic energies in that employees were allowed to work on the Rolling Mill without locking it out in accordance with the written established procedures.