Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
This violation item has been deleted.
Inspection Nr: 109180067
Citation: 02002
Citation Type: Willful
Abatement Date: 08/09/2010 W
Initial Penalty: $70,000.00
Current Penalty: $0.00
Issuance Date: 08/03/2010
Nr Instances: 3
Nr Exposed: 10
Related Event Code (REC):
Gravity: 10
Report ID: 0111500
Contest Date: 08/27/2010
Final Order: 01/06/2012
Emphasis: X
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/06/2012 | $0.00 | 08/09/2010 | Willful | |
Penalty | Z: Issued | 08/03/2010 | $70,000.00 | 08/09/2010 | Willful |
Text For Citation: 02 Item/Group: 002 Hazard: HEAT
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recogn ized hazards that were causing or likely to cause death or serious physical harm in that the method use d to clean the 561 main fuel gas line pipes - blowing natural gas through them a t high velocity - was not implemented in such a way as to protect employees from the hazard of an explosion caused by venting large amounts of natural gas into areas where it could accumulate and where, or in close proximity to where, ignit ion sources existed. The following conditions and practices contributed to the e xistence of this hazard: the vent pipe configured close to and below scaffolding , in close proximity to the Power Generation Building, in the area immediately e ast of the two approximately 115 foot tall Heat Recovery Steam Generators (HRSGs ) and well below the tops of all of those structures; the failure to eliminate o pen flame ignition sources, including but not limited to propane heaters; constr uction work occurring during the gas blow process; individuals other than those essential to conducting the gas blows working in the area during the gas blow pr ocess; and the inability to readily control the amount and pressure of gas flowing through the main gas fuel line. On February 7, 2010, employees were expo sed to serious or fatal impact and other injuries from an explosion hazard creat ed when a large amount of natural gas was blown at high velocity through CT#2 Ma in Knockout Drum Vent Pipe (561-TNK-2002) into the area immediately east of HRSG number 2 and close to buildings, scaffolding, partially enclosed work areas, an d other structures that were adjacent to the Power Generation Building in which employees worked and in or around in which open flame ignition sources, includin g but not limited to propane heaters, existed, construction work was occurring, and numerous employees non-essential to conducting the gas blow were working. Wh en natural gas is chosen for this method of cleaning gas line pipes, feasible me ans of abatement to eliminate or materially reduce the hazard are to ensure that the ve nt pipe is positioned vertically and above the Power Generation Building and all other nearby structures, or horizontally to a location away from structures tha t could inhibit the adequate dispersal of the gas; ensure that any and all ignit ion sources are eliminated; ensure that any and all construction activity ceases during the gas blow process; ensure that all workers other than those essential to conducting the gas blows are removed from the building and area around which the gas blows are occurring; and ensure the use of devices to control the amoun t and pressure of gas vented, such as a fast closing pipe shut-off valve and a g as pressure control valve.