Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1066411.015
Citation: 02002
Citation Type: Willful
Abatement Date: 01/31/2016 2
Initial Penalty: $28,000.00
Current Penalty: $19,600.00
Issuance Date: 11/23/2015
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 12/02/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/02/2015 | $19,600.00 | 01/31/2016 | Willful | |
Penalty | Z: Issued | 11/23/2015 | $28,000.00 | 12/02/2015 | Willful |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). Location: Jobsite An employee was injured when a 6' deep trench that was excavated in sandy, granular material with straight cut walls without any cave-in protection collapsed, partially engulfing the employee.